📢 Noise Pollution Limit Calculator (CPCB Rules, India)

Is that loudspeaker actually over the limit? There is a number for it.

No ratings yet — be the first

Enter details

Log in or create a free account to save your inputs and results, so you don't have to enter them again next time.🔒 No spam, ever. We never sell or share your details, and you can delete your history or account at any time. Privacy policy

Fill in the details and click Calculate to see your results.

Formula at a glance

Noise Limits Calculator: Exceedance — measured − the limit for that zone and time. Example: 62 dB(A) in a residential area at night → Verdict: over the limit by 17 dB
How the Noise Limits Calculator works: Exceedance — measured − the limit for that zone and time

Rate this calculator

Was it useful? A quick star rating helps others — and you can leave a comment too.
Rate it: ★ ★ ★ ★ ★

📘 About the Noise Pollution Limit Calculator

India's Noise Pollution (Regulation and Control) Rules, 2000 set ambient limits in dB(A) Leq for four zones. Residential areas get 55 dB(A) by day and 45 by night; commercial 65 and 55; industrial 75 and 70; and silence zones — within about 100 metres of a hospital, educational institution or court — 50 and 40.

Day runs from 6 am to 10 pm and night from 10 pm to 6 am, which is why a complaint about a wedding band at 11 pm is a stronger one than about the same band at 8 pm. The rules also cap loudspeakers at 10 dB(A) above the ambient limit or 75 dB(A), whichever is lower, and ban them outright between 10 pm and 6 am except inside closed halls, auditoria and banquet halls.

A few decibels over sounds minor and is not. Sound energy doubles every 3 dB, so 17 dB over the limit is about fifty times the energy the limit allows and roughly three times as loud to a listener. Exceedances are measured as Leq over a period, not as the single loudest moment, so a short burst raises a long measurement far less than it feels like it should.

🧮 Formula

Exceedance
measured − the limit for that zone and time
In energy
10^(exceedance ÷ 10) times the allowed energy
In loudness
about 2^(exceedance ÷ 10) times as loud

✏️ Worked examples

62 dB(A) in a residential area at night

You enter
Level you measured (dB(A) Leq)62
ZoneResidential area
TimeNight time — 10 pm to 6 am
You get
Verdictover the limit by 17 dB
The limit here45 dB(A) Leq — Residential area, night time (10 pm to 6 am)
You measured62 dB(A) Leq
In sound energy that is50.1× the energy the limit allows
How it soundsabout 3.2× as loud as the limit
Day limit here55 dB(A) · night limit 45 dB(A)

over the limit by 17 dB — 50.1× the energy the limit allows.

58 dB(A) outside a hospital in the daytime

You enter
Level you measured (dB(A) Leq)58
ZoneSilence zone — near a hospital, school or court
TimeDay time — 6 am to 10 pm
You get
Verdictover the limit by 8 dB
The limit here50 dB(A) Leq — Silence zone — within 100 m of a hospital, school or court, day time (6 am to 10 pm)
You measured58 dB(A) Leq
In sound energy that is6.3× the energy the limit allows
How it soundsabout 1.7× as loud as the limit
Day limit here50 dB(A) · night limit 40 dB(A)

It is over the limit by 8 dB — a silence zone allows only 50 dB(A) by day.

72 dB(A) in a commercial street by day

You enter
Level you measured (dB(A) Leq)72
ZoneCommercial area
TimeDay time — 6 am to 10 pm
You get
Verdictover the limit by 7 dB
The limit here65 dB(A) Leq — Commercial area, day time (6 am to 10 pm)
You measured72 dB(A) Leq
In sound energy that is5× the energy the limit allows
How it soundsabout 1.6× as loud as the limit
Day limit here65 dB(A) · night limit 55 dB(A)

over the limit by 7 dB.

🧭 How to use this calculator

What you enter

  • Level you measured (dB(A) Leq)
  • Zone
  • Time

What you get

  • Verdict
  • The limit here
  • You measured
  • In sound energy that is
  • How it sounds
  • Day limit here

💡 Noise limits under the Noise Pollution (Regulation and Control) Rules, 2000

  • Industrial area — 75 dB(A) day, 70 dB(A) night.
  • Commercial area — 65 dB(A) day, 55 dB(A) night.
  • Residential area — 55 dB(A) day, 45 dB(A) night.
  • Silence zone (within 100 m of a hospital, school or court) — 50 dB(A) day, 40 dB(A) night.
  • Day time is 6 am to 10 pm; night time is 10 pm to 6 am.
  • Loudspeakers are capped at 10 dB(A) above the ambient limit or 75 dB(A), whichever is lower, and are not allowed at all between 10 pm and 6 am except in closed halls.

❓ Frequently asked questions

What is the legal noise limit in a residential area in India?

55 dB(A) Leq during the day (6 am to 10 pm) and 45 dB(A) at night (10 pm to 6 am), under the Noise Pollution (Regulation and Control) Rules, 2000.

What is a silence zone?

The area within about 100 metres of a hospital, educational institution or court, declared as such by the competent authority. The limits are 50 dB(A) by day and 40 by night, and horns, loudspeakers and firecrackers are not allowed there at all.

Are loudspeakers allowed at night?

Not between 10 pm and 6 am, except in closed premises such as auditoria, conference rooms and banquet halls. State governments may permit a limited number of exempted nights a year for festivals.

How loud can a loudspeaker legally be?

10 dB(A) above the ambient limit for that zone, or 75 dB(A), whichever is lower, measured at one metre from the speaker.

Who do I complain to about noise?

The local police and the State Pollution Control Board both have jurisdiction; most states also take complaints on a dedicated app or helpline. A dated recording with a measured level and the time helps.

How do I measure noise properly?

With a sound level meter on A-weighting and slow response, held about 1.2 m above the ground and away from reflecting walls, averaged as Leq over at least a few minutes. Phone apps are indicative and typically a few dB out.