📐 Air Purifier Room Size Calculator: How Big a Room Does It Cover?

Work out what a purifier you own — or are about to buy — really covers.

No ratings yet — be the first

Enter details

On the box or in the manual. Use the smoke or PM2.5 figure, not the pollen one.
Fill this in to find out whether the purifier is enough and how many you need.

Log in or create a free account to save your inputs and results, so you don't have to enter them again next time.🔒 No spam, ever. We never sell or share your details, and you can delete your history or account at any time. Privacy policy

Fill in the details and click Calculate to see your results.

Formula at a glance

Purifier Coverage Calculator: Area covered — CADR ÷ (air changes an hour × ceiling height). Example: 300 m³/h purifier, 10 ft ceiling, 5 ACH → Room this purifier covers: 212 sq ft (19.7 m²)
How the Purifier Coverage Calculator works: Area covered — CADR ÷ (air changes an hour × ceiling height)

Rate this calculator

Was it useful? A quick star rating helps others — and you can leave a comment too.
Rate it: ★ ★ ★ ★ ★

📘 About the Purifier Coverage Calculator

Area covered = CADR ÷ (air changes an hour × ceiling height). A 300 m³/h purifier turns over 60 m³ an hour at 5 air changes, which with a 10 ft ceiling is about 212 sq ft. The same machine would be sold as covering 400-600 sq ft, because the number on the box is usually worked out at 1-2 air changes.

If you already have a room in mind, the useful question is the other way round: how many air changes does this purifier give that room? Below about three, it will shift the readings but not the feel of the room; at five or more it keeps indoor PM2.5 low while outdoor air leaks in.

Purifiers add up. Two of 300 m³/h behave like one of 600, and two placed apart mix the room better than both in a corner. What does not add up is leaving the door open: an open door makes the room as big as the flat, and the purifier starts losing.

🧮 Formula

Area covered
CADR ÷ (air changes an hour × ceiling height)
ACH you get
CADR ÷ (floor area × ceiling height)

✏️ Worked examples

300 m³/h purifier, 10 ft ceiling, 5 ACH

You enter
Purifier CADR300
CADR given inm³/h (cubic metres an hour)
Room measured inFeet & sq ft
Ceiling height (ft or m)10
Air changes an hour you want5 — the AHAM standard (CADR = ⅔ of sq ft)
Your room's floor area (sq ft or m², optional)180
You get
Room this purifier covers212 sq ft (19.7 m²)
At5 air changes an hour, ceiling 3.05 m
CADR300 m³/h (177 cfm)
Volume it can turn over60 m³ at that rate
Your room180 sq ft (16.7 m²) — this purifier gives it 5.9 air changes an hour
Verdictenough on its own
Units needed1 — this one is enough
CADR this room wants255 m³/h (150 cfm)

It properly covers 212 sq ft (19.7 m²). In your room: 180 sq ft (16.7 m²) — this purifier gives it 5.9 air changes an hour.

A 400 cfm unit in a 300 sq ft room

You enter
Purifier CADR400
CADR given incfm (cubic feet a minute)
Room measured inFeet & sq ft
Ceiling height (ft or m)10
Air changes an hour you want5 — the AHAM standard (CADR = ⅔ of sq ft)
Your room's floor area (sq ft or m², optional)300
You get
Room this purifier covers480 sq ft (44.6 m²)
At5 air changes an hour, ceiling 3.05 m
CADR680 m³/h (400 cfm)
Volume it can turn over136 m³ at that rate
Your room300 sq ft (27.9 m²) — this purifier gives it 8 air changes an hour
Verdictenough on its own
Units needed1 — this one is enough
CADR this room wants425 m³/h (250 cfm)

Covers 480 sq ft (44.6 m²). Verdict for a 300 sq ft room: enough on its own.

250 m³/h in a big 400 sq ft hall

You enter
Purifier CADR250
CADR given inm³/h (cubic metres an hour)
Room measured inFeet & sq ft
Ceiling height (ft or m)10
Air changes an hour you want5 — the AHAM standard (CADR = ⅔ of sq ft)
Your room's floor area (sq ft or m², optional)400
You get
Room this purifier covers177 sq ft (16.4 m²)
At5 air changes an hour, ceiling 3.05 m
CADR250 m³/h (147 cfm)
Volume it can turn over50 m³ at that rate
Your room400 sq ft (37.2 m²) — this purifier gives it 2.2 air changes an hour
Verdicttoo small for this room on its own
Units needed3 of these, or one with 566 m³/h CADR
CADR this room wants566 m³/h (333 cfm)

You would need 3 of these, or one with 566 m³/h CADR.

🧭 How to use this calculator

What you enter

  • Purifier CADROn the box or in the manual. Use the smoke or PM2.5 figure, not the pollen one.
  • CADR given in
  • Room measured in
  • Ceiling height (ft or m)
  • Air changes an hour you want
  • Your room's floor area (sq ft or m², optional)Fill this in to find out whether the purifier is enough and how many you need.

What you get

  • Room this purifier covers
  • At
  • CADR
  • Volume it can turn over
  • Your room
  • Verdict
  • Units needed
  • CADR this room wants

💡 Air changes an hour, and what each one is for

  • 2 ACH — enough for smells and light dust, the level most "coverage area" claims on the box are based on.
  • 3-4 ACH — everyday city air; keeps indoor PM2.5 well under the outdoor reading.
  • 5 ACH — the level AHAM's two-thirds rule works out to, and a sensible default.
  • 6-8 ACH — what AQI 200-400 air needs if you want the room genuinely clean.
  • 12 ACH — a smoky room, or a day when the outdoor reading is off the scale.

❓ Frequently asked questions

What room size does a 300 m³/h purifier cover?

About 212 sq ft at 5 air changes an hour with a 10 ft ceiling — or 130 sq ft if you want 8 changes for severe smog.

How do I know if my purifier is big enough?

Divide its CADR by your room's volume. Four or more air changes an hour is comfortable, two or three is weak, and under two will barely register on a bad day.

Do two air purifiers work better than one?

Their CADRs add, so two of 250 m³/h equal one of 500. Spread them out rather than putting both in one corner, and run both on a middle speed instead of one flat out.

Can one purifier do the whole house?

No. Each closed room needs its own air changes; a single unit in the hall with doors open gives every room a fraction of its CADR. Buy per room, or move one unit and close the door.

Why does the box claim a much bigger room?

Because it is quoting 1-2 air changes an hour, which is the standard for odour rather than particulates. Halve or third the claim and you have the real figure.