Enter details
💾Log in or create a free account to save your inputs and results, so you don't have to enter them again next time.🔒 No spam, ever. We never sell or share your details, and you can delete your history or account at any time. Privacy policy
Fill in the details and click Calculate to see your results.
📘 About the Air Purifier Size Calculator
CADR — clean air delivery rate — is the only number worth buying on. It is the volume of genuinely filtered air a purifier delivers each hour, and the required figure is simply your room's volume multiplied by the air changes an hour you want. A 150 sq ft room with a 10 ft ceiling holds 42.5 m³, so 5 air changes an hour needs 212 m³/h of CADR.
AHAM, the American trade body that certifies CADR, gives the rule of thumb the other way round: the smoke CADR in cfm should be at least two-thirds of the floor area in sq ft. That assumes an 8 ft ceiling and works out to about 5 air changes an hour. Indian ceilings are usually 10 ft or more, so the same floor area needs a quarter more CADR than the American rule suggests.
The coverage area printed on a box is usually calculated at 1-2 air changes an hour, which is why a purifier sold for "500 sq ft" often only does 150-200 sq ft properly. And CADR is measured on the highest, noisiest speed — on silent mode expect roughly a third of it, which is the setting most people actually sleep with.
🧮 Formula
✏️ Worked examples
150 sq ft bedroom, 10 ft ceiling, 5 ACH
You get| CADR your room needs | 212 m³/h (125 cfm) |
| At | 5 air changes an hour · room 150 sq ft (13.9 m²) × 3.05 m high |
| Room volume | 42.5 m³ |
| AHAM two-thirds rule | smoke CADR of at least 100 cfm (170 m³/h) — ⅔ of 150 sq ft |
| One air change takes | 12 minutes at this CADR |
| What to look for | a purifier rated 212 m³/h or more for smoke / PM2.5, on its highest speed |
| If you buy 127 m³/h instead | you get 3 air changes an hour — usable, but slower to clear a room |
Look for 212 m³/h (125 cfm). The AHAM rule asks for smoke CADR of at least 100 cfm (170 m³/h) — ⅔ of 150 sq ft.
Delhi winter: same room, 8 air changes
You get| CADR your room needs | 340 m³/h (200 cfm) |
| At | 8 air changes an hour · room 150 sq ft (13.9 m²) × 3.05 m high |
| Room volume | 42.5 m³ |
| AHAM two-thirds rule | smoke CADR of at least 100 cfm (170 m³/h) — ⅔ of 150 sq ft |
| One air change takes | 7.5 minutes at this CADR |
| What to look for | a purifier rated 340 m³/h or more for smoke / PM2.5, on its highest speed |
| If you buy 204 m³/h instead | you get 4.8 air changes an hour — usable, but slower to clear a room |
At 8 air changes an hour the same room needs 340 m³/h (200 cfm).
4 × 5 m living room, 3 m ceiling
You get| CADR your room needs | 300 m³/h (177 cfm) |
| At | 5 air changes an hour · room 215 sq ft (20.0 m²) × 3 m high |
| Room volume | 60.0 m³ |
| AHAM two-thirds rule | smoke CADR of at least 144 cfm (244 m³/h) — ⅔ of 215 sq ft |
| One air change takes | 12 minutes at this CADR |
| What to look for | a purifier rated 300 m³/h or more for smoke / PM2.5, on its highest speed |
| If you buy 180 m³/h instead | you get 3 air changes an hour — usable, but slower to clear a room |
That room needs 300 m³/h (177 cfm).
🧭 How to use this calculator
What you enter
- Room measured in
- Room length (ft or m)
- Room width (ft or m)
- Or total floor area (sq ft or m²)Fill this in instead of the length and width if you already know the area.
- Ceiling height (ft or m)10 ft (3 m) is usual in Indian homes; older houses are higher.
- Air changes an hour you want
What you get
- CADR your room needs
- At
- Room volume
- AHAM two-thirds rule
- One air change takes
- What to look for
- If you buy 122 m³/h instead
💡 Air changes an hour, and what each one is for
- 2 ACH — enough for smells and light dust, the level most "coverage area" claims on the box are based on.
- 3-4 ACH — everyday city air; keeps indoor PM2.5 well under the outdoor reading.
- 5 ACH — the level AHAM's two-thirds rule works out to, and a sensible default.
- 6-8 ACH — what AQI 200-400 air needs if you want the room genuinely clean.
- 12 ACH — a smoky room, or a day when the outdoor reading is off the scale.
❓ Frequently asked questions
What size air purifier do I need for a 150 sq ft room?
About 212 m³/h (125 cfm) of CADR for 5 air changes an hour with a 10 ft ceiling — and closer to 340 m³/h if you want 8 changes on a severe-smog day.
How do I work out CADR from room size?
Multiply floor area by ceiling height to get the volume, then multiply by the air changes an hour you want. Keep the units consistent: m² × m gives m³, and m³ × ACH gives m³/h.
Is the coverage area on the box reliable?
Rarely. Most makers quote it at 1-2 air changes an hour, which is enough for smells but not for PM2.5. Divide the claimed area by two or three for a realistic figure.
How many air changes an hour do I need?
Four to five for ordinary city air, six to eight when the outdoor AQI is 200-400. Below three you will see the benefit in the readings but not feel it.
Should I buy one big purifier or two small ones?
Two add up — two of 250 m³/h behave like one of 500 — and spread round the room they mix the air better. One large unit is quieter and cheaper to re-filter.
Does ceiling height really matter?
Yes. A 10 ft ceiling holds 25% more air than an 8 ft one, so it needs 25% more CADR for the same air changes. Old houses with 12 ft ceilings need half again.