🌀 Air Purifier Size Calculator: What CADR Does My Room Need?

Buy on CADR, not on the coverage area printed on the box.

No ratings yet — be the first

Enter details

Fill this in instead of the length and width if you already know the area.
10 ft (3 m) is usual in Indian homes; older houses are higher.

Log in or create a free account to save your inputs and results, so you don't have to enter them again next time.🔒 No spam, ever. We never sell or share your details, and you can delete your history or account at any time. Privacy policy

Fill in the details and click Calculate to see your results.

Formula at a glance

Purifier Size Calculator: CADR needed — floor area × ceiling height × air changes an hour. Example: 150 sq ft bedroom, 10 ft ceiling, 5 ACH → CADR your room needs: 212 m³/h (125 cfm)
How the Purifier Size Calculator works: CADR needed — floor area × ceiling height × air changes an hour

Rate this calculator

Was it useful? A quick star rating helps others — and you can leave a comment too.
Rate it: ★ ★ ★ ★ ★

📘 About the Air Purifier Size Calculator

CADR — clean air delivery rate — is the only number worth buying on. It is the volume of genuinely filtered air a purifier delivers each hour, and the required figure is simply your room's volume multiplied by the air changes an hour you want. A 150 sq ft room with a 10 ft ceiling holds 42.5 m³, so 5 air changes an hour needs 212 m³/h of CADR.

AHAM, the American trade body that certifies CADR, gives the rule of thumb the other way round: the smoke CADR in cfm should be at least two-thirds of the floor area in sq ft. That assumes an 8 ft ceiling and works out to about 5 air changes an hour. Indian ceilings are usually 10 ft or more, so the same floor area needs a quarter more CADR than the American rule suggests.

The coverage area printed on a box is usually calculated at 1-2 air changes an hour, which is why a purifier sold for "500 sq ft" often only does 150-200 sq ft properly. And CADR is measured on the highest, noisiest speed — on silent mode expect roughly a third of it, which is the setting most people actually sleep with.

🧮 Formula

CADR needed
floor area × ceiling height × air changes an hour
AHAM rule
smoke CADR (cfm) ≥ ⅔ × floor area (sq ft)

✏️ Worked examples

150 sq ft bedroom, 10 ft ceiling, 5 ACH

You enter
Room measured inFeet & sq ft
Room length (ft or m)12
Room width (ft or m)12
Or total floor area (sq ft or m²)150
Ceiling height (ft or m)10
Air changes an hour you want5 — the AHAM standard (CADR = ⅔ of sq ft)
You get
CADR your room needs212 m³/h (125 cfm)
At5 air changes an hour · room 150 sq ft (13.9 m²) × 3.05 m high
Room volume42.5 m³
AHAM two-thirds rulesmoke CADR of at least 100 cfm (170 m³/h) — ⅔ of 150 sq ft
One air change takes12 minutes at this CADR
What to look fora purifier rated 212 m³/h or more for smoke / PM2.5, on its highest speed
If you buy 127 m³/h insteadyou get 3 air changes an hour — usable, but slower to clear a room

Look for 212 m³/h (125 cfm). The AHAM rule asks for smoke CADR of at least 100 cfm (170 m³/h) — ⅔ of 150 sq ft.

Delhi winter: same room, 8 air changes

You enter
Room measured inFeet & sq ft
Room length (ft or m)12
Room width (ft or m)12
Or total floor area (sq ft or m²)150
Ceiling height (ft or m)10
Air changes an hour you want8 — severe smog, AQI 300+
You get
CADR your room needs340 m³/h (200 cfm)
At8 air changes an hour · room 150 sq ft (13.9 m²) × 3.05 m high
Room volume42.5 m³
AHAM two-thirds rulesmoke CADR of at least 100 cfm (170 m³/h) — ⅔ of 150 sq ft
One air change takes7.5 minutes at this CADR
What to look fora purifier rated 340 m³/h or more for smoke / PM2.5, on its highest speed
If you buy 204 m³/h insteadyou get 4.8 air changes an hour — usable, but slower to clear a room

At 8 air changes an hour the same room needs 340 m³/h (200 cfm).

4 × 5 m living room, 3 m ceiling

You enter
Room measured inMetres & m²
Room length (ft or m)4
Room width (ft or m)5
Or total floor area (sq ft or m²)0
Ceiling height (ft or m)3
Air changes an hour you want5 — the AHAM standard (CADR = ⅔ of sq ft)
You get
CADR your room needs300 m³/h (177 cfm)
At5 air changes an hour · room 215 sq ft (20.0 m²) × 3 m high
Room volume60.0 m³
AHAM two-thirds rulesmoke CADR of at least 144 cfm (244 m³/h) — ⅔ of 215 sq ft
One air change takes12 minutes at this CADR
What to look fora purifier rated 300 m³/h or more for smoke / PM2.5, on its highest speed
If you buy 180 m³/h insteadyou get 3 air changes an hour — usable, but slower to clear a room

That room needs 300 m³/h (177 cfm).

🧭 How to use this calculator

What you enter

  • Room measured in
  • Room length (ft or m)
  • Room width (ft or m)
  • Or total floor area (sq ft or m²)Fill this in instead of the length and width if you already know the area.
  • Ceiling height (ft or m)10 ft (3 m) is usual in Indian homes; older houses are higher.
  • Air changes an hour you want

What you get

  • CADR your room needs
  • At
  • Room volume
  • AHAM two-thirds rule
  • One air change takes
  • What to look for
  • If you buy 122 m³/h instead

💡 Air changes an hour, and what each one is for

  • 2 ACH — enough for smells and light dust, the level most "coverage area" claims on the box are based on.
  • 3-4 ACH — everyday city air; keeps indoor PM2.5 well under the outdoor reading.
  • 5 ACH — the level AHAM's two-thirds rule works out to, and a sensible default.
  • 6-8 ACH — what AQI 200-400 air needs if you want the room genuinely clean.
  • 12 ACH — a smoky room, or a day when the outdoor reading is off the scale.

❓ Frequently asked questions

What size air purifier do I need for a 150 sq ft room?

About 212 m³/h (125 cfm) of CADR for 5 air changes an hour with a 10 ft ceiling — and closer to 340 m³/h if you want 8 changes on a severe-smog day.

How do I work out CADR from room size?

Multiply floor area by ceiling height to get the volume, then multiply by the air changes an hour you want. Keep the units consistent: m² × m gives m³, and m³ × ACH gives m³/h.

Is the coverage area on the box reliable?

Rarely. Most makers quote it at 1-2 air changes an hour, which is enough for smells but not for PM2.5. Divide the claimed area by two or three for a realistic figure.

How many air changes an hour do I need?

Four to five for ordinary city air, six to eight when the outdoor AQI is 200-400. Below three you will see the benefit in the readings but not feel it.

Should I buy one big purifier or two small ones?

Two add up — two of 250 m³/h behave like one of 500 — and spread round the room they mix the air better. One large unit is quieter and cheaper to re-filter.

Does ceiling height really matter?

Yes. A 10 ft ceiling holds 25% more air than an 8 ft one, so it needs 25% more CADR for the same air changes. Old houses with 12 ft ceilings need half again.