📘 About the BOD Calculator
BOD is measured by sealing a diluted sample in a 300 mL bottle, keeping it dark at 20 °C for five days and seeing how much dissolved oxygen the micro-organisms used. BOD₅ = (DO at the start − DO at the end) × the dilution factor, and the dilution factor is the bottle volume divided by the sample volume.
The test only counts if the dilution was right. Standard methods want at least 2 mg/L of oxygen consumed and at least 1 mg/L still left after five days, which is why strong samples are run at several dilutions at once — too little sample and the result is noise, too much and the bottle runs out of oxygen and the answer is simply wrong.
COD measures everything chemically oxidisable rather than only what micro-organisms will eat, so it is always the larger number. Their ratio is the quick test of treatability: above about 0.6 the effluent is readily biodegradable, 0.3-0.6 needs acclimatised organisms, and below 0.3 biological treatment will struggle and the load is mostly industrial.
🧮 Formula
✏️ Worked examples
10 mL in a 300 mL bottle, DO 8.2 to 3.1
You get| BOD₅ | 153 mg/L |
| Oxygen used in 5 days | 5.1 mg/L |
| Dilution factor | 30× — 10 mL of sample in a 300 mL bottle |
| BOD/COD ratio | 0.364 — biodegradable with acclimatised organisms |
| COD | 420 mg/L — over the 250 mg/L inland discharge standard |
| Against the inland surface water standard (30 mg/L) | over by 123 mg/L — 5.1× the limit |
| What this water looks like | raw sewage range |
BOD₅ is 153 mg/L, at a dilution factor of 30× — 10 mL of sample in a 300 mL bottle.
Treated effluent: 100 mL sample
You get| BOD₅ | 6.6 mg/L |
| Oxygen used in 5 days | 2.2 mg/L |
| Dilution factor | 3× — 100 mL of sample in a 300 mL bottle |
| Against the inland surface water standard (30 mg/L) | within it |
| What this water looks like | moderately polluted |
BOD₅ 6.6 mg/L.
A known BOD of 45 with COD 150
You get| BOD₅ | 45 mg/L |
| BOD/COD ratio | 0.3 — biodegradable with acclimatised organisms |
| COD | 150 mg/L — within the 250 mg/L inland discharge standard |
| Against the inland surface water standard (30 mg/L) | over by 15 mg/L — 1.5× the limit |
| What this water looks like | raw sewage range |
45 mg/L, and the BOD/COD ratio is 0.3 — biodegradable with acclimatised organisms.
🧭 How to use this calculator
What you enter
- How you want to work it out
- DO at the start (mg/L)
- DO after 5 days at 20 °C (mg/L)
- Sample volume (mL)
- Bottle volume (mL)
- BOD if you already know it (mg/L)
- COD (mg/L, optional)Fill this in for the BOD/COD ratio, which says whether biological treatment will work.
What you get
- BOD₅
- Oxygen used in 5 days
- Dilution factor
- BOD/COD ratio
- COD
- Against the inland surface water standard (30 mg/L)
- What this water looks like
❓ Frequently asked questions
How do you calculate BOD?
BOD₅ = (DO at the start − DO after five days) × the dilution factor, where the dilution factor is the bottle volume divided by the sample volume — 300 mL bottles are standard.
What is a good BOD level?
Below 3 mg/L is clean water, 3-8 moderately polluted, and raw sewage is usually 150-400 mg/L. India's general discharge standard for inland surface water is 30 mg/L.
What is the BOD/COD ratio used for?
Judging treatability. Above 0.6 the waste is readily biodegradable, 0.3-0.6 needs acclimatised organisms, and below 0.3 biological treatment alone will not cope.
Why does the final DO have to stay above 1 mg/L?
Because once the bottle runs out of oxygen the organisms stop, and the measured depletion no longer reflects the real demand. Standard methods also want at least 2 mg/L used.
Why is COD always higher than BOD?
COD oxidises everything chemically oxidisable, including compounds micro-organisms will not touch in five days.
What are India's discharge limits?
Under the general standards: BOD 30 mg/L into inland surface water, 350 into a public sewer, 100 on land for irrigation, and COD 250 mg/L inland.